Kongter’s Application in Data Center

Kongter’s Application in Data Center

Data security is our top concern. Your mission critical power system highly counts on the performance of battery system. Our job is to make sure that your battery backup system is at 100% performances when they are needed. To do this, Kongter supplies a whole of battery test equipments and battery monitoring system with customized and easy going solutions.

All these battery test equipments are compliant with latest IEEE standards for battery maintenance and management including IEEE 450, IEEE 1188, and IEEE1106. We also supply a lot of rack mounted load banks which is widely applied in data center. 

Kongter customized battery load bank DC load unit for telecom power utility
Battery Load Bank
BT-301 Battery Condition Analyzer for fast and accurate test of battery internal resistance/conductance
Battery Handheld Tester
Battery Monitoring System

We offer various customized load banks to meet users’ need precisely. For data center, we have 24V, 48V & other load bank models with high discharge current. All battery load units are powerful with standard discharge function and other functions like parallel load, assistant discharge, charge monitor, etc. >>>View More

Kongter offers BT-301 quick tester for measurement of battery internal resistance (or conductance) for users in different countries. It measures battery voltage, internal resistance (or conductance) and judge battery capacity in seconds. It could also test batteries under float charge.  >>>View More

BMS-3923 is complete monitoring system for all industries battery online monitor and battery management. With simply a smart phone, you could easily access to your batteries with complte data. For telecom, Kongter has typical solutions especially for system consist of 4x12V cells. >>>View More

Kongter customized AC load bank resistive dummy load bank
Rack Mounted AC Load Bank
Kongter test & measurement equipment
Battery Activator
K-3838- ground fault locator
Ground Fault Locator

Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
>>>View More

It is compact unit for regular maintenance of single battery, especially for old cell. It plays three roles in one unit: charger, discharger and activator. In activation mode, lag-out battery will experience low-volt constant current charging and discharging in one or multi-circles.   >>>View More

Kongter’s ground fault locators are delicate to fast detect, trace and pinpoint virtual grounding faults on DC systems where there is current breakage to ground. They save you from long time unnecessary troubleshooting and helps to increase stability of electrical equipment. >>>View More